null
×
close
+1.262.989.4882

Monday - Friday, 8AM - 4PM CST

Select Fireplace Brand
Select Fireplace Model
Select Category
click to zoom in

Lennox & Country Winslow Pellet Stove Igniter w/ Clamp (H6005)

(No reviews yet) Write a Review
$89.00
SKU:
H6005-AMP
UPC:
658354100053
Condition:
New
Availability:
Ships in 1 - 2 business days
Shipping:
Ships to USA & Canada

This igniter is designed to provide the most durable construction and consistently reliable starts for your stove. The igniter is extremely durable and mounts using a hose clamp that secures the igniter in place.

We offer the best prices on the highest quality replacement parts for Country Pellet Stoves and have the knowledge to help you make the right decision before you place an order. 

Replacement For Part Number:

  • H6005

Technical Specs:

  • Igniter Length- 5 1/2"
  • Tube Length- 6 1/2"
  • Igniter Diameter- 5/16"
  • Tube Diameter- 7/8"
  • Volts- 120
  • Watts- 400

Instructions:

  1. UNPLUG THE UNIT FROM ITS POWER SOURCE
  2. Locate which side of the unit your convection blower (room blower) is located and remove the panels to gain access.
  3. On freestanding units, you will need to disconnect the wiring harness from the controller. The panels are removed by lifting them and then tilting them out from the bottom. The rear panel can be removed by loosening the ⅛” Allan key screws from around the rear access panel and lifting the panel slightly. The screws do not need to be removed, just loosened.
  4. On insert models, removed the outer decorative trim from the surround. Use the flat-head screwdriver to loosen the two screws that hold the left side panel to the unit and remove the panel. The unit may need to be pulled forward on the hearth about a foot to gain visual access to the components. 
  5. Loosen, but do not remove the two Allen key screws that hold the blower on the mount and then remove the blower. You may need to cut the zip-ties that secure the black wires to the wiring harness. Once the wires are free, remove the blower wires from the fan switch and the terminal block to separate the blower from the unit.
  6. Locate the igniter. Loosen the worm clip that secures the igniter to the mounting bracket and then remove the igniter by pulling it out. Traces the white wires from the igniter, cutting all zip-ties that may fasten it to the wiring harness. Unplug one end from the terminal block and the other from the purple wire going back to the controller.
  7. Before installing your new igniter, make sure that your burn pot is on the stove and aligned properly. As you slide the new igniter into the stove, the burn pot will act as a guide. The igniter tube MUST seat against the burnpot. Once it is seated, tighten the igniter tube in place with the worm clip.
  8. Plug-in your igniter wires. The bulleted end goes to the purple wire. The ¼” female goes anywhere on the terminal block. Secure any loose wires with zip-ties.
  9. Connect wires BEFORE reinstalling the blower. Make sure that one black wire is connected to the fan switch (fan switch is the one with the yellow wire). Connect the other black wire for the blower anywhere on the terminal block under the auger motor. Reinstall your blower with the gasket. Fasten any loose wires with zip-ties.
  10. You’re done!